Resolution: standard / high Figure 2.
Pulmonary function testing. A. Airway resistance in WT vs. gp91phox-/-. Symbols used are white triangle WA (Wildtype
alum), black circles WO (WT OVA), white cross in black box NOX (alum gp91phox-/-)
and black box NOXO (OVA treated gp91phox-/-). Airway resistance obtained by invasive
plethysmography show increased values in both gp91phox-/- and gp91phoxMM12 double
knockout mice compared to wildtype post-OVA. Symbols used are open square WA, closed
square WO, open triangle DKOA (alum double knockout), closed triangle DKOO (OVA treated
DKO. On d 22, 24 h after the last intra-tracheal allergen (OVA) challenge invasive
pulmonary mechanics were measured using a commercial plethysmography system (Model
PLY4111 plethysmograph, MAX II amplifier and pressure transducer system, and Biosystem
XA software, Buxco Electronics, Inc.) mice receiving aerosolized solutions of methacholine
(0, 3.125, 6.25, 12.5, 25, 50, and 100 mg/ml in normal saline) via an AER 1021 nebulizer
aerosol system (Buxco Electronics, Inc., Wilmington, NC) with 2.5-4 micron aerosol
particle size generated by NEB0126 nebulizer head (Nektar Therapeutics, San Carlos,
CA), and RL as calculated from measures of pressure and flow and expressed as cmH2O/ml/s
was determined. Figures show Airway resistance (RL) values ± SEM of data obtained
from 3 independent experiments (n = 5/group). C. Non-invasive plethysmography (expressed as Penh) was also assessed on d 22 in independent
experiments with gp91phox-/- only and this co-related with the airway resistance values
obtained by invasive plethysmography. Symbols used are black diamond WA, open triangle
NOX, small black square WO, open large square NOXO: For non-invasive plethysmography,
mice were challenged with increasing doses of aerosolized methacholine (0, 5, and
20, 40, and 100 mg/ml in normal saline) generated by an ultrasonic nebulizer (DeVilbiss
Health Care, Inc., Somerset, PA) for 2 min. and the degree of bronchoconstriction
was expressed as enhanced pause (Penh), a calculated dimensionless value that correlates
with measurement of airway resistance, impedance, and intrapleural pressure. Penh
is primarily independent of FRC, tidal volume, and respiratory rate since the ratio
of measurements is obtained during the same breath and has a strong correlation with
both airway resistance (Raw) measured directly in anesthetized, tracheotomized, and
mechanically ventilated mice. *denotes p value < 0.01 compared to post-OVA wildtype
values.
Banerjee and Henderson Clinical and Molecular Allergy 2012 10:2 doi:10.1186/1476-7961-10-2 |